Archives
- June 2026
- November 2025
- October 2025
- September 2024
- October 2023
- August 2023
- January 2023
- December 2022
- October 2022
- September 2022
- June 2022
- March 2021
- August 2020
- June 2020
- December 2019
- October 2019
- September 2019
- July 2019
- June 2019
- May 2019
- April 2019
- January 2019
- November 2018
- September 2018
- August 2018
- March 2018
- September 2017
- July 2017
- June 2017
- April 2017
- November 2016
- August 2016
- March 2016
- November 2015
- September 2015
- August 2015
- July 2015
- March 2015
- February 2015
- October 2014
- September 2014
- July 2014
- June 2014
- May 2014
- January 2014
- September 2013
- June 2013
- April 2013
- March 2013
- February 2013
- January 2013
- December 2012
- June 2011
-
Meta
Author Archives: mwaring708
NECyto 2014 and some updates
The New England Cytometry Users Group would like to announce the date for our annual Fall meeting. It will be on October 2nd from 8:00 am to 5 pm at the beautiful Starr Center at the Schepens Eye Research Institute in … Continue reading
Posted in Uncategorized
Leave a comment
2013 Salary Survey
–Thanks to Stephen Kwok at the Tufts Laser Cytometry Flow Core at Tufts Medical School for conducting a flow cytometry salary survey last year, the results were posted to the Purdue list but have since been removed, so we are … Continue reading
Posted in Uncategorized
Leave a comment
One of these things is not like the others…
For those of you that grew up with Sesame Street: Three of these things belong together Three of these things are kind of the same Can you guess which one of these doesn’t belong here? Now it’s time to play … Continue reading
Posted in Humor
Leave a comment
Bee-ah-core or Bye-ah-core?
We have a Biacore 3000 from GE Healthcare, which uses Surface Plasmon Resonance technology (SPR) to perform label-free measurements of protein interactions, as well as detect differences in concentrations of solutions. This technology can determine binding kinetics and protein interactions … Continue reading
Posted in Humor
Leave a comment
Comp Comp
Compensation Comparison I often hear of people looking at a compensation matrix and deciding if it is “good” or “bad”. The actual values in themselves don’t give enough information to make this determination. Voltages can be set to give you … Continue reading
Posted in Uncategorized
Leave a comment
You have chosen… poorly
It was brought to my attention that the filter on our 3 laser LSR2 might not be optimal for the AmCyan channel (490/40 bandpass, also used for Horizon V500, CFP, Aqua Live/Dead dye, and Q525)–it was centered on the peak … Continue reading
Posted in Uncategorized
Leave a comment
Staying focused….
Just a quick post since we are in the midst of relocating to a new facility…
Posted in Uncategorized
Leave a comment
As bright or brighter…
So the earlier posts were a lead-in to this one, which I hope will clarify this important issue in compensation. When calculating compensation, it is important to make sure that your single stained control is as bright or brighter than … Continue reading